69 research outputs found

    Micro-precision control/structure interaction technology for large optical space systems

    Get PDF
    The CSI program at JPL is chartered to develop the structures and control technology needed for sub-micron level stabilization of future optical space systems. The extreme dimensional stability required for such systems derives from the need to maintain the alignment and figure of critical optical elements to a small fraction (typically 1/20th to 1/50th) of the wavelength of detected radiation. The wavelength is about 0.5 micron for visible light and 0.1 micron for ultra-violet light. This lambda/50 requirement is common to a broad class of optical systems including filled aperture telescopes (with monolithic or segmented primary mirrors), sparse aperture telescopes, and optical interferometers. The challenge for CSI arises when such systems become large, with spatially distributed optical elements mounted on a lightweight, flexible structure. In order to better understand the requirements for micro-precision CSI technology, a representative future optical system was identified and developed as an analytical testbed for CSI concepts and approaches. An optical interferometer was selected as a stressing example of the relevant mission class. The system that emerged was termed the Focus Mission Interferometer (FMI). This paper will describe the multi-layer control architecture used to address the FMI's nanometer level stabilization requirements. In addition the paper will discuss on-going and planned experimental work aimed at demonstrating that multi-layer CSI can work in practice in the relevant performance regime

    Space science/space station attached payload pointing accommodation study: Technology assessment white paper

    Get PDF
    Technology assessment is performed for pointing systems that accommodate payloads of large mass and large dimensions. Related technology areas are also examined. These related areas include active thermal lines or power cables across gimbals, new materials for increased passive damping, tethered pointing, and inertially reacting pointing systems. Conclusions, issues and concerns, and recommendations regarding the status and development of large pointing systems for space applications are made based on the performed assessments

    Molecular composition and photochemical lifetimes of brown carbon chromophores in biomass burning organic aerosol

    Get PDF
    To better understand the effects of wildfires on air quality and climate, it is important to assess the occurrence of chromophoric compounds in smoke and characterize their optical properties. This study explores the molecular composition of light-absorbing organic aerosol, or brown carbon (BrC), sampled at the Missoula Fire Sciences laboratory as a part of the FIREX Fall 2016 lab intensive. A total of 12 biomass fuels from different plant types were tested, including gymnosperm (coniferous) and angiosperm (flowering) plants and different ecosystem components such as duff, litter, and canopy. Emitted biomass burning organic aerosol (BBOA) particles were collected onto Teflon filters and analyzed offline using high-performance liquid chromatography coupled to a photodiode array spectrophotometer and a high-resolution mass spectrometer (HPLC-PDA-HRMS). Separated BrC chromophores were classified by their retention times, absorption spectra, integrated absorbance in the near-UV and visible spectral range (300-700 nm), and chemical formulas from the accurate m/z measurements. BrC chromophores were grouped into the following classes and subclasses: lignin-derived products, which include lignin pyrolysis products; distillation products, which include coumarins and flavonoids; nitroaromatics; and polycyclic aromatic hydrocarbons (PAHs). The observed classes and subclasses were common across most fuel types, although specific BrC chromophores varied based on plant type (gymnosperm or angiosperm) and ecosystem component(s) burned. To study the stability of the observed BrC compounds with respect to photodegradation, BBOA particle samples were irradiated directly on filters with near UV (300-400 nm) radiation, followed by extraction and HPLC-PDA-HRMS analysis. Lifetimes of individual BrC chromophores depended on the fuel type and the corresponding combustion condition. Lignin-derived and flavonoid classes of BrC generally had the longest lifetimes with respect to UV photodegradation. Moreover, lifetimes for the same type of BrC chromophores varied depending on biomass fuel and combustion conditions. While individual BrC chromophores disappeared on a timescale of several days, the overall light absorption by the sample persisted longer, presumably because the condensed-phase photochemical processes converted one set of chromophores into another without complete photobleaching or from undetected BrC chromophores that photobleached more slowly. To model the effect of BrC on climate, it is important to understand the change in the overall absorption coefficient with time. We measured the equivalent atmospheric lifetimes of the overall BrC absorption coefficient, which ranged from 10 to 41 d, with subalpine fir having the shortest lifetime and conifer canopies, i.e., juniper, having the longest lifetime. BrC emitted from biomass fuel loads encompassing multiple ecosystem components (litter, shrub, canopy) had absorption lifetimes on the lower end of the range. These results indicate that photobleaching of BBOA by condensed-phase photochemistry is relatively slow. Competing chemical aging mechanisms, such as heterogeneous oxidation by OH, may be more important for controlling the rate of BrC photobleaching in BBOA

    Computational controls for aerospace systems

    Get PDF
    The goal is to develop the next generation guidance and control analysis and design tools to enable future missions and to improve productivity and reliability

    Optical systems integrated modeling

    Get PDF
    An integrated modeling capability that provides the tools by which entire optical systems and instruments can be simulated and optimized is a key technology development, applicable to all mission classes, especially astrophysics. Many of the future missions require optical systems that are physically much larger than anything flown before and yet must retain the characteristic sub-micron diffraction limited wavefront accuracy of their smaller precursors. It is no longer feasible to follow the path of 'cut and test' development; the sheer scale of these systems precludes many of the older techniques that rely upon ground evaluation of full size engineering units. The ability to accurately model (by computer) and optimize the entire flight system's integrated structural, thermal, and dynamic characteristics is essential. Two distinct integrated modeling capabilities are required. These are an initial design capability and a detailed design and optimization system. The content of an initial design package is shown. It would be a modular, workstation based code which allows preliminary integrated system analysis and trade studies to be carried out quickly by a single engineer or a small design team. A simple concept for a detailed design and optimization system is shown. This is a linkage of interface architecture that allows efficient interchange of information between existing large specialized optical, control, thermal, and structural design codes. The computing environment would be a network of large mainframe machines and its users would be project level design teams. More advanced concepts for detailed design systems would support interaction between modules and automated optimization of the entire system. Technology assessment and development plans for integrated package for initial design, interface development for detailed optimization, validation, and modeling research are presented

    Correlations of EGFR mutations and increases in EGFR and HER2 copy number to gefitinib response in a retrospective analysis of lung cancer patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Gefitinib, a small molecule tyrosine kinase inhibitor of the Epidermal Growth Factor Receptor (<it>EGFR</it>), has shown limited efficacy in the treatment of lung cancer. Recognized clinical predictors of response to this drug, specifically female, non-smoker, Asian descent, and adenocarcinoma, together suggest a genetic basis for drug response. Recent studies have addressed the relationship between response and either sequence mutations or increased copy number of specific receptor tyrosine kinases. We set out to examine the relationship between response and the molecular status of two such kinases, <it>EGFR </it>and <it>HER2</it>, in 39 patients treated with gefitinib at the BC Cancer Agency.</p> <p>Methods</p> <p>Archival patient material was reviewed by a pathologist and malignant cells were selectively isolated by laser microdissection or manual recovery of cells from microscope slides. Genomic DNA was extracted from 37 such patient samples and exons 18–24, coding for the tyrosine kinase domain of <it>EGFR</it>, were amplified by PCR and sequenced. <it>EGFR </it>and <it>HER2 </it>copy number status were also assessed using FISH in 26 samples. Correlations between molecular features and drug response were assessed using the two-sided Fisher's exact test.</p> <p>Results</p> <p>Mutations previously correlated with response were detected in five tumours, four with exon 19 deletions and one with an exon 21 missense L858R point mutation. Increased gene copy number was observed in thirteen tumours, seven with <it>EGFR </it>amplification, three with <it>HER2 </it>amplification, and three with amplification of both genes. In our study cohort, a correlation was not observed between response and <it>EGFR </it>mutations (exon 19 deletion p = 0.0889, we observed a single exon 21 mutation in a non-responder) or increases in <it>EGFR </it>or <it>HER2 </it>copy number (p = 0.552 and 0.437, respectively).</p> <p>Conclusion</p> <p>Neither mutation of <it>EGFR </it>nor increased copy number of <it>EGFR </it>or <it>HER2 </it>was diagnostic of response to gefitinib in this cohort. However, validation of these features in a larger sample set is appropriate. Identification of additional predictive biomarkers beyond <it>EGFR </it>status may be necessary to accurately predict treatment outcome.</p
    • …
    corecore